Skip to content.
Return to Department of Building and Housing home page.

Quick reference guide: Building categories for commercial and mixed-use buildings

Quick reference guide: Building categories for commercial and mixed-use buildings
Quick reference guide: Building categories for commercial and mixed-use buildings
 X means not allowed in this category
  Cat. 2 Cat. 3
Structure No limits apply
 
Use (ref Building [Specified Systems, Change the Use, and Earthquake-prone Buildings] Regulations 2005)
SH: Single residential dwelling Use other check sheet
SR: Semi-detached / duplex  
SR: eg multi-unit flats, apartments  
SA: eg motels, hotels  
WL: eg offices, service provision, light manufacturing  
WM: eg manufacturing, storage facilities  
CS, CL, CM, CO: eg cafés, cinemas, schools, retail space  
SC: eg hospitals, care facilities for aged Cross. Category 3 only
SD: eg detention quarters, prisons Cross.
WH: eg chemical manufacturing or processing plants, spray painting operations Cross.
WF: eg bulk storage warehouses for flammable liquids/gases Cross.
 
Importance level (ref AS/NZS 1170.0 Table 3.2)
1. Structures presenting a low degree of hazard to life and other property Outbuildings and ancillary buildings not included in LBP scheme
2. Normal structures and structures not in other importance levels    
3. Structures that as a whole contain people in crowds or contents of high value to the community or pose risks to people in crowds (eg medical centres, schools, transport terminals) Cross. Category 3 only
4. Structures with special post-disaster functions (eg police stations, fire stations, ambulance bays) Cross.
5. Special structures (not yet defined) Cross.
 
Building height
Occupied floors that are 10 metres or more above the exit Cross. Category 3 only
 
Occupant numbers
  No limits in Category 3
Category 2 limits on the number of occupants, based on floor height and use:
Floor level Use →
Total allowed SA, SR CS, CL, CM, CO WL, WM
Ground floor up to 500 ≤ 50 ≤ 500 ≤ 500
1st floor (< 4m) up to 250 ≤ 25 ≤ 250 ≤ 250
2nd and 3rd floors 4m to < 10m up to 100 ≤ 25 0 ≤ 100
 
Risk score (ref Compliance Document E2/AS1)  
  No limits apply

Status under the Historic Places Act (ref www.historic.org.nz)

No status No limits apply
Category 2 Historic Place Cat. 2 or Cat. 3
Category 1 Historic Place Cross. Category 3 only